The appearance of the JWD2-…JD terminal is consistent with that of the JWD2-… terminal. They are ground terminals.
Insertion of the terminal on the guide rail can ensure correct mechanical and electric connections
The JWD2-…JD can meet all the technical requirements of IEC60947-7-2, especially in the following aspects
– Low contact resistance;
– Corrosion resistance of the contact;
– Yellow + green housing;
– Multiple identification digits
| Rigid solid | Flexible multi-conductor | |
| (mm2) | |
IEC 60947-7-2 | 0.2-4 | 0.2-2.5 | |
Description |
Color |
Type |
Spring-cage terminal mounted on |
Yellow + green |
JWD2-2.5a/2JD |
(1) End plate |
Grey |
G-D2-2.5a/2 |
(2) Plug-in bridgeware used for horizontal connection in the terminal center |
2 digits |
|
|
3 digits |
|
|
4 digits |
|
|
5 digits |
|
|
10 digits |
|
|
20 digits |
|
(3) Double-tagging bracket inserted in the double-layer spring-cage terminal JWD2…/2, identified with ZP5 and ZBFM5 |
ZP-a/ZJ2 |
(4) Screwdriver for spring-cage terminal operation |
SZF 1-0.6X3.5 |
(5) Flat quick designation strip, with 100 digits for lateral identification |
ZBFM5 |
(6) Test plug |
Grey |
|
Terminal dimensions |
|
|
Thickness / length / end plate thickness |
[mm] |
5.2/67.5/2.2 |
Height (TH 35:7.5 / TH 35:15) |
[mm] |
47.5/55 |
Technical data in accordance with IEC/DIN VDE standards |
|
|
Maximum rated working current / cross-sectional area |
[A] / [mm2] |
— |
Rated impulse withstand voltage / degree of pollution |
[KV] / - |
6月3日 |
Over-voltage category / insulation material group |
- / - |
III/1 |
Connection |
|
|
Stranded wire with tubular pre-insulated terminal |
[mm2] |
0.25-2.5 |
Stranded wire with tubular bare terminal |
[mm2] |
0.25-2.5 |
|
|
|
Stripping length |
[mm] |
10 |
Plug gauge (IEC60947-1) |
|
A3 |
Insulation material |
|
PA |
Grading as per UL 94 |
|
V0 |
Certification data (UL and CSA/CUL) |
|
|
Rated working voltage / rated working current / wire gauge |
UL: [V]/[A]/AWG |
12月26日 |