For power distribution, the application of the three-conductor spring terminal JWD2.../1-2 can greatly save the space and costs.
Actually, one terminal is usually required to connect three conductors. The terminal (/1-2) can connect three conductors without any additional terminals or bridgeware.
The connection mode of the general-purpose FBS plug-in bridgeware can achieve horizontal connection of adjacent straight-way terminals.
For power distribution, the application of the three-conductor spring terminal JWD2…/1-2 can greatly save the space and costs.
Actually, one terminal is usually required to connect three conductors. The terminal (/1-2) can connect three conductors without any additional terminals or bridgeware.
The connection mode of the general-purpose FBS plug-in bridgeware can achieve horizontal connection of adjacent straight-way terminals.
Rigid solid
Flexible multi-conductor
I
Ui
(mm2)
(A)
(V)
IEC 60947-7-1
0.2-4
0.2-2.5
28*
800
* The total current of all connections should not exceed the maximum load current.
Description
Color
Type
Part Number
Package quantity
Spring-cage terminal mounted on
Grey
JWD2-2.5a/1-2
51 31 24 1
85
Blue
JWD2-2.5a/1-2BU
51 31 25 4
85
(1) End plate
Grey
G-D2-2.5a/1-2
51 30 48 8
50
(2) Plug-in bridgeware used for horizontal connection in the terminal center
2 digits
FBS 2-5
Imax:24A
51 30 16 1
200
3 digits
FBS 3-5
24A
51 30 17 4
200
4 digits
FBS 4-5
24A
51 30 18 7
200
5 digits
FBS 5-5
24A
51 30 19 0
100
10 digits
FBS 10-5
24A
51 30 21 3
100
20 digits
FBS 20-5
24A
51 30 22 6
50
(3) Conversion bridgeware for connecting JWD2-6a/1-2 to JWD2-2.5a/1-2 or JWD2-4a/1-2
(4) Group partition for terminal group display and electric isolation, with thickness of 2 mm
GF-D2-a/1-2
51 30 78 9
50
(5) Screwdriver for spring-cage terminal operation
SZF 1-0.6X3.5
02 04 51 7
10
(6) Quick tag, with 10 digits for identification in the terminal center
ZP5
8 868 102
100
(7) Quick designation strip, with 100 digits for lateral identification
ZBFM5
0 903 595
1000
(8) Test plug
Grey
PS-5
9311173
10
Terminal dimensions
Thickness / length /end plate thickness
[mm]
5.2 / 60.5 / 2.2
Height (TH 35:7.5 / TH 35:15)
[mm]
36.5/44
Technical data in accordance with IEC/DIN VDE standards
Maximum rated working current / cross-sectional area
[A] / [mm2]
4月28日
Rated impulse withstand voltage / degree of pollution
[KV] / -
8月3日
Over-voltage category / insulation material group
- / -
lll/l
Connection
Stranded wire with tubular pre-insulated terminal
[mm2]
0.25-2.5
Stranded wire with tubular bare terminal
[mm2]
0.25-2.5
Stripping length
[mm]
10
Plug gauge (IEC60947-1)
A3
Insulation material
PA
Grading as per UL 94
V0
Certification data (UL and CSA/CUL)
Rated working voltage / rated working current / wire gauge