The JWD2 straight-way spring-cage terminal is featured by its compact design and optimum connection solution. The front connection of the JWD2 series eliminates the required space between two wiring ducts.
Double bridges can achieve chain bridging.
Corresponding accessories can be used for testing and identification.
The JWD2 spring-cage terminal series provides terminals with the cross-sectional areas of 1.5 mm2, 2.5 mm2, 4 mm2 and 6 mm2, as well as products with the cross-sectional area from 10 mm2 to 35 mm2
The JWD2 straight-way spring-cage terminal is featured by its compact design and optimum connection solution. The front connection of the JWD2 series eliminates the required space between two wiring ducts.
Double bridges can achieve chain bridging.
Corresponding accessories can be used for testing and identification.
The JWD2 spring-cage terminal series provides terminals with the cross-sectional areas of 1.5 mm2, 2.5 mm2, 4 mm2 and 6 mm2, as well as products with the cross-sectional area from 10 mm2 to 35 mm2
Rigid solid
Flexible multi-conductor
I
Ui
(mm2)
(A)
(V)
IEC 60947-7-1
0.2-4
0.2-2.5
31
800
Description
Color
Type
Spring-cage terminal mounted on
Grey
JWD2-2.5a
Blue
JWD2-2.5a BU
(1) End plate
Grey
G-D2-2.5a
(2) Plug-in bridgeware used for horizontal connection in the terminal center
2 digits
FBS 2-5
lmax:24A
3 digits
FBS 3-5
24A
4 digits
FBS 4-5
24A
5 digits
FBS 5-5
24A
10 digits
FBS 10-5
24A
20 digits
FBS 20-5
24A
(3) Conversion bridgeware for connecting JWD2-6a to JWD2-2.5a or JWD2-4a
(4) Group partition for terminal group display and electric isolation, with thickness of 2 mm
GF-D2-4a
(5) Warning panel mounted at the operation port of the JWD2 "Miniature Spring" spring-cage terminal
WST2.5
(6) Screwdriver
SZF 1-0. 6X3.5
(7) Quick tag, with 10 digits for identification in the terminal center
ZP5
(8) Quick designation strip, with 100 digits for lateral identification
ZBFM5
(9) Test plug
Grey
PS-5
Terminal dimensions
Thickness / length /end plate thickness
[mm]
5.2/48.8/2.2
Height (TH 35:7.5 / TH 35:15)
[mm]
36.5/44
Technical data in accordance with IEC/DIN VDE standards
Maximum rated working current / cross-sectional area
[A] / [mm2]
31/4
Rated impulse withstand voltage / degree of pollution
[KV] / -
8月3日
Over-voltage category / insulation material group
- / -
III/I
Connection
Stranded wire with tubular pre-insulated terminal
[mm2]
0.25-2.5
Stranded wire with tubular bare terminal
[mm2]
0.25-2.5
Stripping length
[mm]
10
Plug gauge (IEC60947-1)
A3
Insulation material
PA
Grading as per UL 94
V0
Certification data (UL and CSA/CUL)
Rated working voltage / rated working current / wire gauge