Language

Current Language
    Change Language
    HomeProductsDin-Rail Terminal blocksSpring-Cage Type DIN-Rail TBSpring-Cage Double Layer Phase Conductor & Ground Din-Rail Terminal blockJWD2-2.5a/2-JD/L Spring-Cage Double Layer Phase Conductor & Ground Din-Rail TB

    Products Category

    JWD2-2.5a/2-JD/L Spring-Cage Double Layer Phase Conductor & Ground Din-Rail TB

    JWD2-2.5a/2-JD/L Spring-Cage Double Layer Phase Conductor & Ground Din-Rail TB

    Share:

    Product Description

    Parameters

    Certification

    Double-Layer Phase Conductor & Ground Type

    Double-Layer Null Line & Ground Type

    Double-Layer Phase Conductor & Null Line Type

    (IEC)(mm2)Rigid solidFlexible multi-conductorI(A)Ui(V)
    DIN VDE 06110.2-40.2-2.532500
    Description Color Type
    Spring-cage terminal mounted on Grey JWD2-2.5a/2-JD/L
    (1) End plate Grey G-D2-2.5a/2
    (2) Plug-in bridgeware used for horizontal connection in the terminal center 2 digits FBS 2-5 Imax:20A
      3 digits FBS 3-5 20A
      4 digits FBS 4-5 20A
      5 digits FBS 5-5 20A
      10 digits FBS 10-5 20A
      20 digits FBS 20-5 20A
    (3) Group partition for terminal group display and electric isolation, with thickness of 2 mm GF-D2-a/2-2
    (4) Double-tagging bracket inserted in the double-layer spring-cage terminal JWD2…/2, identified with ZP5 and ZBFM5 ZP-a/ZJ2
    (5) Warning panel mounted at the operation port of the D2 "Miniature Spring" spring-cage terminal   WST2.5
    (6) Screwdriver   SZF 1-0.6X3.5
    (7) Quick designation strip, with 100 digits for lateral identification White ZBFM5
    (8) Test plug Grey  

    Terminal dimensions

     

     

    Thickness / length / end plate thickness

    [mm]

    5.2/67.5/2.2

    Height (TH 35:7.5 / TH 35:15)

    [mm]

    47.5 / 55

    Technical data in accordance with IEC/DIN VDE standards

     

     

    Maximum rated working current / cross-sectional area

    [A] / [mm2]

    32/4

    Rated impulse withstand voltage / degree of pollution

    [KV] / -

    6/3

    Over-voltage category / insulation material group

    - / -

    III/I

    Connection

     

     

    Stranded wire with tubular pre-insulated terminal

    [mm2]

    0.25-2.5

    Stranded wire with tubular bare terminal

    [mm2]

    0.25-2.5

     

     

     

    Stripping length

    [mm]

    10

    Plug gauge (IEC60947-1)

     

    A3

    Insulation material

     

    PA

    Grading as per UL 94

     

    V0

    Certification data (UL and CSA/CUL)

     

     

    Rated working voltage / rated working current / wire gauge

    UL: [V]/[A]/AWG

    CSA/CUL: [V]/[A]/AWG

    300/20/26-12

    -