Terminal thickness: 8.2 | ||||
Solid conductor | Stranded conductor | I | Ui | |
(mmz) | (A) | (V) | ||
0.5-10 | 0.5-6 | 57 | 400 | |
IEC 60947-7-1 |
Products Category
JWD1-6S Screw Type Switching TB for Breaking Capacity
Product Description
Parameters
Certification
Description | Schematic diagram | Type | |||
Test terminal: | JWD1-6S | ||||
With general-purpose locating base, suitable for standard mounting rails | |||||
and | |||||
Switching terminal: | |||||
With general-purpose locating base, suitable for standard mounting rails | |||||
and | |||||
(1) End plate: | 6S G | ||||
One additional piece must be attached to the end of each terminal strip set. If it is mounted in the center of the terminal strip, the creepage distance may increase. | |||||
(2) Central liaison part: | ZL 6S/10 | ||||
It is used to connect terminals with the same specification and form a liaison terminal group; each part has 10 digits (supplied with screws) that can be further divided at will. | |||||
(3) Edge liaison part | 2 digits: | ||||
Its role is the same as that of the central liaison part (2); with insulation on the back side; 10 digits that can be further divided at will | |||||
3 digits: | |||||
10 digits: | |||||
(4) Divider: | 6S GP (Thickness 0.8mm) | ||||
It is used to separate two adjacent liaison terminal groups and can be inserted after assembly, without any effect on the overall space. | |||||
(5) Group partition: | 6S GF (Thickness 0.8mm) | ||||
Used for separation of each terminal group; with dual effects (visible grouping and electrical isolation) | |||||
(6) Central liaison part | |||||
It is used to connect terminals with the same specification and form a liaison terminal group; each part has 10 digits (supplied with screws) that can be further divided at will. | |||||
(7) Switch liaison part | HL 6S/2-1 | ||||
It can be used on both sides of the breaking sliding block for two terminals; the strap of the liaison part is pushed inwards to make it break; two screws are supplied. | |||||
(8) Switch liaison part | HL 6S/2-2 | ||||
It can be used on both sides of the breaking sliding block for two terminals; the strap of the liaison part is pushed outwards to make it break; two screws are supplied. | |||||
(9) Switch liaison part | HL 6S/2 | ||||
It is used for two terminals; please note that it can only be used on the right of terminals; two screws are supplied. | |||||
(10) Switch liaison part | HL 6S/4 | ||||
It is used for the short circuit of a three-phase interconnected current transformer and can only be used on the right of the terminal; 1) four screws are supplied. | |||||
(11) Test plug: | ZP8/10 | ||||
(12) Conversion test plug: | |||||
(13) Tag: |
Terminal dimensions |
|
|
||
Thickness / width / end plate thickness |
[mm] |
8.2/72/2.2 |
||
Height (TH 35:7.5 / TH 35:15 / G 32:15) |
[mm] |
51.5/59/56 |
||
Technical data based on IEC/DIN VDE standards |
|
|
||
Maximum rated working current / cross-sectional area |
[A]/ [mm] |
57/10 |
||
Maximum cross-sectional area of conductors (rigid / flexible) that can be connected if any edge liaison part is used |
[mm2] |
- |
||
Rated impulse withstand voltage / degree of pollution |
[kV]/- |
6/3 |
||
Over-voltage category / insulation material group |
-/- |
III/I |
||
Connection capacity |
|
|
||
Flexible conductor with tubular bare terminal / tubular pre-insulated terminal |
[mm2] |
0.5-6 / 0.5-4 |
||
Connection of multiple conductors (connecting two conductors with the same cross-sectional area) |
|
|
||
Rigid conductor / flexible conductor |
[mm2] |
0.5-2.5/0.5-6 |
||
Flexible conductor with tubular bare terminal |
[mm2] |
0.5-4 |
||
Flexible conductor with DEV-tubular pre-insulated terminal |
[mm2] |
0.5-4 |
||
Stripping length |
[mm] |
13 |
||
Screw for terminal position: screw / torque |
[Nm] |
M4/1.5-1.8 |
||
Screw for breaking sliding block: screw / torque |
[Nm] |
M3.5/1.0-1.3 |
||
Insulation material type |
|
PA |
||
Material flammability according to UL94 |
|
V0 |
||
Rated working voltage / rated working current / wire gauge |
UL:[V]/[A]/AWG |
300/50/26-8 |