Terminal thickness: 6.2 | ||||
Rigid conductor | Flexible conductor | I | Ui | |
(mm2) | (A) | (V) | ||
0.2-4 | 0.2-4 | 16 | 800 | |
IEC 60947-7-1 |
Products Category
JWD1-4K Screw Type Switching TB for Breaking Capacity
Product Description
Parameters
Certification
Description | Schematic diagram | Type | |||
Test terminal: | |||||
With general-purpose locating base, suitable for standard mounting rails | |||||
and | |||||
Switching terminal: | JWD1-4K | ||||
With general-purpose locating base, suitable for standard mounting rails | |||||
and | |||||
(1) End plate: | |||||
One additional piece must be attached to the end of each terminal strip set. If it is mounted in the center of the terminal strip, the creepage distance may increase. | |||||
(2) Central liaison part: | |||||
It is used to connect terminals with the same specification and form a liaison terminal group; each part has 10 digits (supplied with screws) that can be further divided at will. | |||||
(3) Edge liaison part | 2 digits: | BL6/2 | |||
Its role is the same as that of the central liaison part (2); with insulation on the back side; 10 digits that can be further divided at will | BL6/3 | ||||
BL6/10 | |||||
3 digits: | |||||
10 digits: | |||||
(4) Divider: | |||||
It is used to separate two adjacent liaison terminal groups and can be inserted after assembly, without any effect on the overall space. | |||||
(5) Group partition: | |||||
Used for separation of each terminal group; with dual effects (visible grouping and electrical isolation) | |||||
(6) Central liaison part | |||||
It is used to connect terminals with the same specification and form a liaison terminal group; each part has 10 digits (supplied with screws) that can be further divided at will. | |||||
(7) Switch liaison part | |||||
It can be used on both sides of the breaking sliding block for two terminals; the strap of the liaison part is pushed inwards to make it break; two screws are supplied. | |||||
(8) Switch liaison part | |||||
It can be used on both sides of the breaking sliding block for two terminals; the strap of the liaison part is pushed outwards to make it break; two screws are supplied. | |||||
(9) Switch liaison part | |||||
It is used for two terminals; please note that it can only be used on the right of terminals; two screws are supplied. | |||||
(10) Switch liaison part | |||||
It is used for the short circuit of a three-phase interconnected current transformer and can only be used on the right of the terminal; 1) four screws are supplied. | |||||
(11) Test plug: | ZP6 | ||||
(12) Conversion test plug: | |||||
(13) Tag: |
Terminal dimensions | |||
Thickness / width / end plate thickness | [mm] | 6.2/51 /- | |
Height (TH 35:7.5 / TH 35:15 / G 32:15) | [mm] | 58.5 / 66 / 63.5 | |
Technical data based on IEC/DIN VDE standards | |||
Maximum rated working current / cross-sectional area | [A]/ [mm] | 4月16日 | |
Maximum cross-sectional area of conductors (rigid / flexible) that can be connected if any edge liaison part is used | [mm2] | 4月4日 | |
Rated impulse withstand voltage / degree of pollution | [kV]/- | 8月3日 | |
Over-voltage category / insulation material group | -/- | III/I | |
Connection capacity | |||
Flexible conductor with tubular bare terminal / tubular pre-insulated terminal | [mm2] | 0.25-4 / 0.25-2.5 | |
Connection of multiple conductors (connecting two conductors with the same cross-sectional area) | |||
Rigid conductor / flexible conductor | [mm2] | 0.2-1.5/0.2-1.5 | |
Flexible conductor with tubular bare terminal | [mm2] | 0.25-1.5 | |
Flexible conductor with DEV-tubular pre-insulated terminal | [mm2] | 0.5-2.5 | |
Stripping length | [mm] | 8 | |
Screw for terminal position: screw / torque | [Nm] | M 3/0.6-0.8 | |
Screw for breaking sliding block: screw / torque | [Nm] | — | |
Insulation material type | PA | ||
Material flammability according to UL94 | V0 | ||
Rated working voltage / rated working current / wire gauge | UL:[V]/[A]/AWG | 600/15/22-12 |