Terminal thickness: 5.08 | |||||
Rigid conductor | Flexible conductor | I | Ui | ||
(mm2) | (A) | (V) | |||
IEC 60947-7-1 | 0.2-4 | 0.2-2.5 | 12 | 250* | |
Products Category
JWD1-2.5V/5.08 Nail type TB
Product Description
Parameters
Certification
Description |
Color |
Type |
|
Terminal: With general-purpose locating base, suitable for standard mounting rails and |
Grey |
JWD1-2.5V/5.08 |
|
Terminal: With general-purpose locating base, suitable for standard mounting rails and |
Grey |
|
|
Protective cover |
JWD1-2.5VF/24 |
||
(1) End plate One additional piece must be attached to the end of each terminal strip set. If it is mounted in the center of the terminal strip, the creepage distance may increase. |
Grey Blue |
JWD1-2.5V/5.08G |
|
(2) Central liaison part: It is used to connect terminals with the same specification and form a liaison terminal group; each part has 10 digits (supplied with screws) that can be further divided at will. |
ZL5/10 |
||
(3) Edge liaison part: Its role is the same as that of the central liaison part (2); with insulation on the back side; 10 digits that can be further divided at will |
2 digits: |
|
|
3 digits: |
|
||
10 digits: |
|
||
(4) Divider It is used to separate two adjacent liaison terminal groups and can be inserted after assembly, without any effect on the overall space. |
GP-1 |
||
(5) Tag: It can be quickly inserted in the upper grooves on both sides of the terminal as a whole for any identification. It has a total of 10 digits (to be divided at will); white |
ZP5 |
Terminal dimensions |
|
|
Thickness / width / end plate thickness |
[mm] |
5.08/47.75/2.5 |
Height (TH 35:7.5 / TH 35:15 / G 32:15) |
[mm] |
47/54.5/52 |
Technical data based on IEC/DIN VDE standards |
|
|
Maximum rated working current / cross-sectional area |
[A] / [mm2] |
12/4 |
Maximum cross-sectional area of conductors (rigid / flexible) that can be connected if any edge liaison part is used: |
[mm2] |
4/2.5 |
Rated impulse withstand voltage / degree of pollution |
[kV]/- |
4/3 |
Over-voltage category / insulation material group |
-/- |
lll/l |
Connection capacity |
|
|
Flexible conductor with tubular bare terminal / tubular pre-insulated terminal |
[mm2] |
0.25-2.5/0.25-1.5 |
Connection of multiple conductors (two conductors with the same cross-sectional area) |
|
|
Rigid conductor / flexible conductor |
[mm2] |
0.2-1.5 / 0.2-1 |
Flexible conductor with tubular bare terminal |
[mm2] |
0.5-1 |
Flexible conductor with DEV-tubular pre-insulated terminal |
[mm2] |
|
Stripping length |
[mm] |
8 |
Screw type |
|
M3 |
Torque |
[Nm] |
0.5-0.6 |
Insulation material type |
|
PA |
Material flammability according to UL94 |
|
V0 |
Rated working voltage / rated working current / wire gauge |
UL: [V]/[A]/AWG |
300/10/22-12 |