Terminal thickness: 10.2 | ||
Rigid conductor | Flexible conductor | |
(mm2) | ||
IEC 60947-7-2 | 0.5-16 | 0.5-10 |
Products Category
JWD1-10JD Screw Type General Din-Rail TB
Product Description
Parameters
Certification
Description | Type | |
Ground terminal: The yellow-green insulating housings can be mounted on the mounting rails and |
JWD1-10 JD | |
Edge liaison part: Its role is the same as that of the central liaison part; with insulation on the back side; 10 digits that can be further divided at will |
2 digits | BL 10/2 |
3 digits | BL10/3 | |
10 digits | BL 10/10 | |
Edge liaison part: Its role is the same as that of the central liaison part; with insulation on the back side, inserted in the conductor holder, and clamped on the insulation housing of the terminal |
2 digits | |
3 digits | ||
Prismatic conductor holder: A prismatic metal block used to compensate the pressed flat conductor |
||
Terminal fastener: (thickness: 10) It is used to finally fix a large-current terminal; after it is pushed, it can be mounted on Type TH35/15 mounting rail, and it should be fixed with two screws. |
ZG1 | |
Tag: It can be quickly inserted in the upper grooves on both sides of the terminal as a whole for any identification. It has a total of 10 digits (to be divided at will); it is white. |
ZP10 |
Terminal dimensions | ||
Thickness / width | [mm] | 10.2/42.5 |
Height (TH 35:7.5 / TH 35:15 / G 32:15) | [mm] | 47/54.5/52 |
Technical data based on IEC/DIN VDE standards | ||
Maximum rated working current / cross-sectional area | [A] / [mm2] | 76/16 |
Rated impulse withstand voltage / degree of pollution | [kV]/- | 8/31) |
Over-voltage category / insulation material group | -/- | lll/l |
Connection capacity | ||
Flexible conductor with tubular bare terminal / tubular pre-insulated terminal | [mm2] | 0.5-10/0.5-0.6 |
Connection of multiple conductors (two conductors with the same cross-sectional area) | ||
Rigid conductor / flexible conductor | [mm2] | 0.5 -4 / 0.5-4 |
Flexible conductor with tubular bare terminal | [mm2] | 0.5-0.25 |
Flexible conductor with DEV-tubular pre-insulated terminal | [mm2] | 0.5-6 |
Stripping length | [mm] | 10 |
Screw for terminal position: screw type / torque | -/[Nm] | M4/1.5-1.8 |
Central fastening screw: screw type / torque | -/[Nm] | M4/1.5-1.8 |
Insulation material type | PA | |
Material flammability according to UL94 | V0 | |
Rated working voltage / rated working current / wire gauge | UL: [V]/[A]/AWG | -/-/24-6 |
Note: When an edge liaison part is used, a cable below 1.5 mm2 should be used for a 2.5 mm2 terminal; corresponding cables should be used for terminals with other cross-sectional areas (mm2). |
Welcome to consult us for more information!