Convenient electric potential collection or distribution
Less space required due to compact structure
Standard plug-in bridgeware can be used for bridging.
The 2.3 mm standard test aperture ensures easy testing.
Large-area identification option
Products Category
Convenient electric potential collection or distribution
Less space required due to compact structure
Standard plug-in bridgeware can be used for bridging.
The 2.3 mm standard test aperture ensures easy testing.
Large-area identification option
Product Description
Parameters
Certification
Convenient electric potential collection or distribution
Less space required due to compact structure
Standard plug-in bridgeware can be used for bridging.
The 2.3 mm standard test aperture ensures easy testing.
Large-area identification option
Technical Data | |||||
Dimensions | Width | Length | Height (TH 35/7,5) | ||
[mm] | 16.3 | 110.5 | 48.8 | ||
Maximum Electrical Data | Imax [A] | Umax [V] | Max Ø [mm2] | AWG (UL) | |
105 | 1000 | 1.5 - 50 | 2月14日 | ||
IEC 60947-7-1 | |||||
Ratings for screw fastening | IEC | IEC/ EN 60079-7 | |||
Nominal working voltage | [V] | 1000 | - | ||
Rated current / cross-section | [A] / [mm2] | 105 | - | ||
Connection capacity | AWG | 16 - 1/0 | 2月14日 | - | |
Connection capacity for screw fastening | Rigid | Flexible | Crimp terminal | ||
with / without plastic sleeve | |||||
Single conductor | [mm2] | 1.5 - 50 | 1.5 - 50 | 1.5 - 35 | 1.5 - 35 |
Twin-conductor (same type) | [mm2] | 1.5 - 16 | 1.5 - 10 | 1.5 - 10 | - |
Rating data, 4 in-line self-holding terminal positions, 6 mm2 | IEC | UL / CUL | CSA | IEC/ | |
EN 60079-7 | |||||
Rated current / cross-section | [A] / [mm2] | Jun-41 | - | - | - |
Connection capacity | AWG | 8月20日 | 2月14日 | 2月14日 | - |
Connection capacity, 4 in-line self-holding terminal positions, 6 mm2 | Rigid | Flexible | Crimp terminal | ||
with / without plastic sleeve | |||||
Single conductor | [mm2] | 0.5 - 10 | 0.5 - 6 | 0.5 - 6 | 0.5 - 6 |
Cross-section for directly pluggable connection | [mm2] | 1月10日 | - | 1月6日 | 1月6日 |
Rating data, 6 in-line self-holding terminal positions, 2.5 mm2 | IEC | UL / CUL | CSA | IEC/ EN 60079-7 | |
Rated current / cross-section | [A] / [mm2] | 24 / 2.5 | - | - | - |
Connection capacity | AWG | 12月26日 | - | - | - |
Connection capacity, 6 in-line self-holding terminal positions, 2.5 mm2 | Rigid | Flexible | Crimp terminal | ||
with / without plastic sleeve | |||||
Single conductor | [mm2] | 0.14 - 4 | 0.14 - 2.5 | 0.14 - 2.5 | 0.14 - 2.5 |
Cross-section for directly pluggable connection | [mm2] | 0.34 - 4 | - | 0.34 - 2.5 | 0.34 - 2.5 |
General parameters | |||||
Stripping length | [mm] | 18 | |||
Thread | M6 | ||||
Tightening torque | [Nm] | 3.2 - 3.7 | |||
Insulation material | PA | ||||
Flammability according to UL 94 | V0 |
Order Data | ||||
Description | Position No. | Color | Type | Imax |
Terminal | Grey | GZ-35/4X6+6X2.5 | ||
Blue | GZ-35/4X6+6X2.5 BU | |||
Black / yellow | GZ-35/4X6+6X2.5 FE |
Accessories | ||||
Block terminal that can be connected to the side slot quickly | Grey | AGK 4-UT 35 | ||
Plug-in bridgeware | ||||
2 | Red | FBS 2-8 | 41 A | |
3 | Red | FBS 3-8 | 41 A | |
4 | Red | FBS 4-8 | 41 A | |
5 | Red | FBS 5-8 | 41 A | |
10 | Red | FBS 10-8 | 41 A | |
Metal part of test plug, with the diameter of 2.3 mm | Grey | MPS-MT | ||
Insulating sleeve for MPS metal part | Red | MPS-IH RD | ||
Combined test plug for testing separate mounting of connector identification | Red | PS-6 | ||
Screwdriver | SZF 3-1,0X5,5 | |||
Identification of central and side marking slots | ZP10 | |||
ZBFM8 |